LOARD_MIV_FULL.pdf[1]-6.pdf | Vacuum Tube | X Ray

Description
GE Medical Systems Lorad M-IV Mammography System XR Lorad M-IV Mammography Alignment and Calibration System Component Locations Error Codes
Categories
Published
of 183
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Share
Transcript
  GE Medical SystemsLorad M-IV Mammography SystemXR Lorad M-IV Mammography System This program and its contents are RESTRICTED to GE Medical Systems andapproved licensees. For GE Medical Systems and approved licensee personnelonly. If you are not a GE Medical Systems or approved licensee employee, you mustclose this application immediately. Disclosure to third parties prohibited. GES-produced documents are not intended for use as documentation for field-baseddiagnostic imaging equipment. Copyright GE Medical Systems 2002. How to Use this EPSTSelf-Paced Training ModulesReference MaterialsFeedback to Author Notes Alignment and CalibrationComponent LocationsError CodesFunctional ChecksLogic and Block DiagramsPreventive MaintenanceSoftware and DiagnosticsTheoryTroubleshooting  GE Medical SystemsLorad M-IV Mammography SystemAlignment and Calibration Alignment & CalibrationComponentLocationsError CodesFunctional ChecksLogic & BlockDiagramsPreventiveMaintenanceSoftware & DiagnosticsTheoryTrouble-shootingSelf-PacedTrainingNotes A LIGNMENT   AND  C ALIBRATION System ControlOverallHost Microprocessor Board SwitchesChange System Default SettingsSoftwareLoad System SoftwareX-Ray GenerationIR Microprocessor kV ControlHigh Voltage AdjustmentHV Control Board Overcurrent/Overvoltage AdjustmentmA ControlTube Current AdjustmentFilament Control Board Overcurrent/Overvoltage AdjustmentX-Ray TubeLine Regulation CheckX-Ray Tube Type SelectionTube Bias Voltage AdjustmentCollimationX-Ray Beam Adjustment-Large Focal SpotX-Ray Beam Adjustment-Small Focal SpotAEC CalibrationImage Receptor DetectionMIII-Style Bucky CalibrationPatient PositioningCompressionForce CalibrationThickness CalibrationCompression Chain Tension CalibrationSetting Compression Release DistanceCompression Accessory Detection Continued on Next Page  GE Medical SystemsLorad M-IV Mammography SystemAlignment and Calibration Alignment & CalibrationComponentLocationsError CodesFunctional ChecksLogic & BlockDiagramsPreventiveMaintenanceSoftware & DiagnosticsTheoryTrouble-shootingSelf-PacedTrainingNotes Motor/Lamp ControlLight Field Brightness AdjustmentLight Field AlignmentPower DistributionAC Power DistributionAccessoriesID Flasher   GE Medical SystemsLorad M-IV Mammography SystemAlignment and Calibration Alignment & CalibrationComponentLocationsError CodesFunctional ChecksLogic & BlockDiagramsPreventiveMaintenanceSoftware & DiagnosticsTheoryTrouble-shootingSelf-PacedTrainingNotes System Control Overall Note Some jumper settings may be different, depend-ing on upgrades, updates, etc. Always verify cor-rect setting in the OEM documentation.   Circuit BoardJumper Number Jumper Position Host Microprocessor Board J1pins 1 & 2 Motor/Lamp Control Board CJ-32pins 2 & 3Motor/Lamp Control BoardJ1pins 1 & 2Motor/Lamp Control BoardJ2openMotor/Lamp Control BoardJ3openMotor/Lamp Control BoardJ4openMotor/Lamp Control BoardJ5pins 1 & 2Motor/Lamp Control BoardJ6pins 1 & 2Motor/Lamp Control BoardJ7pins 1 & 2Motor/Lamp Control BoardJ8pins 1 & 2Motor/Lamp Control BoardJ9pins 1 & 2 Image Receptor Microprocessor Board JP1openImage Receptor Microprocessor BoardJP2pins 1 & 2 Continued on Next Page
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks